Supporting Structure
The roof deck must have suitable strength, condition and compatibility with the intended waterproofing assembly.
A detailed guide to reinforced bituminous roof membranes, their historical development, modern construction, performance, common defects and refurbishment.
Torch-on felt remains an established waterproofing method for many commercial and industrial flat roofs. Its performance depends on sound roof design, suitable materials, competent installation and appropriate maintenance.
Torch-on felt roofing is a type of reinforced bituminous waterproofing system in which heat is used to bond compatible membranes to a prepared roof surface or underlying layer.
Modern products generally consist of a reinforcement carrier, modified bitumen and protective surface finishes, manufactured into flexible rolls.
During suitable torch-applied installation, controlled heat softens the relevant bituminous surface to create adhesion between compatible layers.
Systems are commonly installed using multiple membranes, although construction varies by manufacturer and specification.
Typical applications include commercial buildings, industrial roof areas, extensions, plant rooms and other low-pitched roofing constructions.
Despite the name, torch-on felt is not simply the same material as older traditional roofing felt. Modern reinforced membranes often contain polymer-modified bitumen and engineered carriers.
Bituminous waterproofing has developed from early natural asphalt applications into modern reinforced membrane systems manufactured for engineered flat roofs.
Natural bitumen and related materials were used historically for sealing and waterproofing in selected building and engineering applications.
Industrialisation encouraged the manufacture of sheet materials impregnated or coated with bituminous substances to provide weather resistance.
Multi-layer bituminous roof coverings became increasingly established in commercial and industrial construction. Traditional systems often relied on hot bitumen or other bonding methods.
Developments in polymer chemistry, reinforcement materials and manufacturing supported more advanced waterproofing membranes.
Reinforced modified-bitumen membranes and torch-applied installation became widely recognised methods for flat roof construction and refurbishment.
Contemporary systems incorporate tested materials, specific substrate requirements and detailed installation guidance. Where torching presents an unacceptable or uncertain fire risk, flame-free methods are required.
A bituminous roofing system must function as a complete assembly, with suitable structural support, insulation, membranes, joints and drainage details.
Conceptual warm roof showing a cap sheet, underlay, insulation, vapour control and supporting deck. Actual build-ups differ between approved systems.
The roof deck must have suitable strength, condition and compatibility with the intended waterproofing assembly.
Warm-roof designs commonly incorporate thermal insulation and a suitable vapour-control strategy to manage condensation risk.
Compatible reinforced bituminous membranes form the waterproof covering, with joints and interfaces designed as part of the system.
An appropriate cap sheet may include mineral surfacing to protect the membrane against environmental exposure.
Some systems combine different application methods. Self-adhesive or mechanically fixed products may be required in areas where a flame would create a fire risk. The complete build-up must follow the selected manufacturer's specification.
Modern torch-on roofing commonly uses bitumen modified with polymers to produce specific flexibility, temperature and installation characteristics.
Styrene-butadiene-styrene modified bitumen is commonly associated with elastomeric characteristics and flexibility.
The actual performance depends on the product formulation and reinforcement.
Atactic polypropylene modified bitumen generally provides plastomeric characteristics suited to selected roofing applications.
Specification must consider temperature, substrate and product compatibility.
Polyester, glass-fibre and composite carriers help provide dimensional and mechanical properties within the membrane.
Many cap sheets incorporate a mineral-granule finish to provide a protective external surface.
Compatible systems may use torch bonding, self-adhesion, mechanical restraint or other approved approaches.
Tested roof systems should be selected for their intended conditions, performance and installation requirements.
The chemistry alone does not determine overall roof performance. Individual membrane construction, reinforcement, testing, manufacturer recommendations and system compatibility remain important.
Reinforced bituminous roofing remains widely used because it offers established waterproofing technology and a variety of engineered system options.
Properly specified and installed membranes form a continuous waterproof layer across suitable roof areas and details.
Reinforcement carriers provide useful strength and dimensional properties within the membrane.
Suitable bituminous systems can be designed for different deck types, roof geometries and building uses.
Certain multi-layer systems provide additional waterproofing layers and engineered joint arrangements.
Where suitable, some existing bituminous membranes can be repaired or overlaid using compatible systems.
Bituminous roofing has an extensive history of use, with many established products, manufacturers and technical specifications.
Like other waterproofing materials, bituminous membranes can deteriorate through ageing, movement, weather exposure and defective detailing.
Problems may appear at seams, outlets, upstands, roof edges or around penetrations.
Some older systems can become brittle or experience cracking, blistering and surface deterioration.
Trapped moisture within the roof build-up can affect insulation, adhesion and the suitability of further refurbishment.
The apparent position of a leak inside a building does not always correspond with its point of entry through the waterproofing.
Moisture or trapped gases can produce localised raised areas in some bituminous coverings.
Poor bonding, deterioration or movement may cause seams to lose weathertightness.
Ageing, stress or inappropriate movement accommodation can damage membranes.
Defective drainage, poor falls or structural deflection may allow water to accumulate.
Failed vertical detailing, flashings and penetrations can create leakage paths.
Foot traffic, dropped tools and roof-mounted plant maintenance can damage the waterproofing.
The use of propane gas torches can create significant fire hazards, particularly near combustible or concealed building materials.
Roof edges, timber substrates, openings, cladding, rooflights and service penetrations can introduce particular concerns.
The NFRC's Safe2Torch approach requires risks to be identified during survey and specification.
Where a fire risk is identified or cannot be ruled out, compatible torch-free solutions should be specified.
Torches should never be applied directly to timber decks or timber upstands.
Any hot works must be planned, controlled and undertaken by competent operatives under a suitable safe system of work.
Safe2Torch is a safety specification approach, not a guarantee that every torch-applied installation is safe. Risk assessment, product selection, competent installation and appropriate supervision are essential.
An existing felt roof may be repairable or suitable for a compatible overlay, depending on the membrane condition and underlying structure.
Examine membranes, laps, outlets, upstands and previous repairs to establish the cause of defects.
Determine whether moisture has entered insulation or other materials and assess the condition of the deck.
Suitable local defects may be repaired using compatible manufacturer-approved materials and methods.
Some existing roofs may accept an appropriately designed overlay after necessary preparation and assessment.
Compatible liquid waterproofing may be considered for selected existing bituminous substrates.
Extensive deterioration, saturated insulation or unsuitable existing construction may make full replacement more appropriate.
An additional waterproofing layer may conceal existing deterioration if the roof is not properly investigated. Material compatibility, adhesion, moisture and structural suitability must be considered.
Felt is one of several waterproofing technologies. The appropriate choice depends on the building, substrate, risk profile and project objectives.
| System | Material | Installation Approach | Key Consideration |
|---|---|---|---|
| Torch-on felt | Modified bituminous membrane | Controlled torch bonding in suitable areas | Fire risk and compatible specification |
| Single-ply | Synthetic sheet membrane | System-dependent welding, bonding or fixing | Correct jointing and compatibility |
| Silicone | Liquid-applied silicone elastomer | Approved liquid coating application | Adhesion and substrate suitability |
| GRP | Glass-reinforced resin | Resin and reinforcement application | Deck movement, curing and detailing |
| Roof coatings | Various liquid-applied systems | Product-specific application | Certified intended use and substrate condition |
Reinforced bituminous roofing remains relevant to the UK construction and refurbishment sectors through its use on commercial, industrial and public-sector buildings.
Retail, office and leisure premises may incorporate bituminous flat roofing on extensions, plant areas and main roofs.
Schools, healthcare buildings and other public assets often require ongoing flat roof maintenance and renewal.
Factories and warehouses may incorporate bituminous waterproofing in low-pitched roof assemblies and associated structures.
Existing roof stock creates a continuing requirement for inspections, repairs, overlays and replacement projects.
Roof renewal may allow opportunities to improve insulation, subject to building design and regulations.
Owners must assess repair costs, roof condition, disruption and future maintenance when deciding how to invest.
Not exactly. Modern torch-on membranes commonly use reinforced and polymer-modified bitumen, while older roofing felts varied considerably in composition and application method.
SBS and APP are different polymer modifiers used in bitumen membranes. Their characteristics vary, and specific product performance must be assessed against the roof requirements.
A gas torch must not be applied directly to a timber deck or timber upstand. Suitable flame-free protection and system arrangements are required in relevant areas.
Some defects can be repaired using compatible materials and suitable methods. Extensive deterioration or moisture damage may require broader refurbishment or replacement.
Certain liquid-applied waterproofing systems may be compatible with suitable existing bituminous membranes. The substrate, moisture, surface preparation and product approvals must be checked.
There is no universal service life. Longevity depends on the membrane, specification, installation, exposure, detailing and maintenance. Product warranties are not necessarily equivalent to the actual service life.
This page provides educational information and is not an installation specification. Project-specific assessment, product instructions and safe systems of work remain essential.
Educational content prepared: November 2026. Consult current manufacturer, fire-safety and roofing guidance before work.
Elite Waterproofing provides commercial and industrial flat roof waterproofing, repair, refurbishment and replacement services.
If an existing felt roof is leaking, deteriorating or approaching the point where renewal may be necessary, contact our team to discuss suitable assessment and potential solutions.
Request a Free Quote